Feed water requirement:
1.Resource:RO water,conductivity<20μs/cm,better<10μs/cm;
2.PH:6.5-9.0;
3.Water temperature:5-35
;
4.Hardness(as CaCO3): <0.5 ppm;
5.Organics:<0.5 ppm,TOC recommended to be 0 ppm;
6.Oxidizers:<0.05ppm,Cl2:0.05ppm, O3:0.02ppm,better both to be 0 ppm.
7.Metals:<0.01 ppm;
8.Silica:<0.5 ppm;
9.Carbon dioxide:<5 ppm;
10.Oil:not detectable.

 
 